Experimental research for γ-ray interference threshold of high electromagnetic pulse sensor

Hedianzixue Yu Tance Jishu/Nuclear Electronics and Detection Technology(2010)

引用 0|浏览5
暂无评分
摘要
The high electromagnetic pulse (EMP) sensor using optical-fiber to transmit signal can restrain electromagnetic interference. The Compton electrons scattered by γ-ray irradiated from nuclear explosion or nuclear explosion simulator can generate EMPand γ-ray, and γ-ray can penetrate the shielding box and irradiate the integrated circuit directly. The γ-ray irradiation effect includes interference, latch up and burn out, these will make the measurement result unbelievable. In this paper, the experimental method researching the γ-ray irradiation effect of high electromagnetic pulse sensor on Qiangguang-I accelerator is introduced. The γ-ray dose rate interference threshold is 2×106Gy(Si)/S. © 2010 IEEE.
更多
查看译文
关键词
sensors,electromagnetic pulse,electromagnetic interference