Application of protective stents in endovascular repair of acute complicated stanford type B aortic dissections

JOURNAL OF ENDOVASCULAR THERAPY(2013)

Cited 15|Views17
No score
Abstract
Purpose: To describe the use of protective stents in the endovascular repair of acute complicated Stanford type B aortic dissections. Methods: From 2009 to 2011, 33 patients (27 men; mean age 47 years, range 31-73) with acute complicated Stanford type B aortic dissection underwent thoracic endovascular aortic repair (TEVAR) assisted by protective stents. In all cases, the proximal and distal landing zones differed in size by >5 mm, and the primary entry tear was in the proximal descending aorta. A bare self-expanding stent (protective stent) was deployed initially at the intended distal landing site of the primary stent-graft in the true lumen. The intention was that the bare stent would prevent excessive dilation of the distal end of the stent-graft in the vicinity of the entry tear, thus avoiding intimal rupture. Results: Successful stent deployment and sealing of the entry tear was achieved in all patients. The median diameter and length of the protective bare stents was 20.3 mm (range 18-24) and 72.7 mm (range 60-80), respectively, while the corresponding dimensions of the covered stent-grafts were 32.8 mm (range 26-40) and 157.4 mm (range 120-200 mm), respectively. There was no stent twisting, migration, of rupture of the false or true lumen. Computed tomography 1 week postoperatively demonstrated closure of the primary entry tear with thrombosis of the false lumen in all cases. No patients were lost to follow-up, which has ranged from 3 months to 3 years. No late endoleaks or stent complications, such as angulation, dislodgment, persistent leaks, branch obstruction, or stent-graft migration, have been observed, and there has been no chronic progressive true or false lumen dilatation, recurrences, or deaths. Conclusion: Adjunctive use of a protective stent when treating acute Stanford type B aortic dissections in which the diameters of the proximal and distal landing zones differ by >5 mm is feasible and safe and provides good short-term outcomes. J Endovasc Ther. 2013;20:210-218
More
Translated text
Key words
bare metal stent,aortic dissection,thoracic endovascular aortic repair,type B dissection,stent-graft,entry tear,aortic diameter,true lumen,false lumen,thrombosis
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined