An Improved Thermal Model for Power Transformers with Dynamic Loading

Power and Energy Engineering Conference(2012)

引用 1|浏览1
暂无评分
摘要
This paper proposed an improved thermal-circuit model for power transformer hot-spot temperature prediction with dynamic loading. The influences of solar radiation and the environmental temperature on the heat dissipation were also considered. When calculating the heat dissipation from the transformer tank to surroundings, the average oil temperature was selected as the node value in the thermal circuit. The new thermal models will be validated with the delivery experimental data of a 220kV-300MVA unit and a 220kV-75MVA unit.
更多
查看译文
关键词
transformer oil,dynamic-loading,thermal-circuit method,sunlight,cooling,environmental temperature,temperature,power transformer hot-spot temperature prediction,apparent power 75 mva,voltage 220 kv,heat dissipation,transformer tank,dynamic loading,power transformer insulation,improved thermal-circuit model,oil viscosity,apparent power 300 mva,solar radiation,average oil temperature,power transformers,mathematical model,heating