Chrome Extension
WeChat Mini Program
Use on ChatGLM

两种游离棉酚检测方法对常规棉粕检测的比较

Animal Husbandry and Feed Science(2011)

Cited 1|Views13
No score
Abstract
主要针对常规棉籽粕(游离棉酚含量200~1000mg/kg)中游离棉酚含量的检测,用美国油化学家学会官方方法AOCSBa7-58和国标GB13086方法作对比检测,以比较2种方法的差异和对结果的影响。参照AOCSBa7-58制定标准曲线,计算换算因子F1,AOCSBa7-58和GB13086的回收率检验,并选择3种游离棉酚含量梯度的常规棉粕测定游离棉酚含量。AOCSBa7-58标准曲线换算因子F1=0.370,R2=0.999,回收率101.14%,RSD=2.56;GB13086质量吸收系数,游离棉酚为62.5L/(cm·g),回收率104.98%,RSD=9.85。结果表明,AOCSBa7-58对棉酚及其衍生物的提取充分,检测结果稳定,重复性好;而GB13086对棉酚及其衍生物的提取不稳定,时高时低,造成检测结果的不稳定性,重复性差。建议饲料行业应由AOCSBa7-58代替GB13086检测棉粕及饲料中游离棉酚含量,更能体现棉粕及饲料中"棉毒素"的含量。
More
Translated text
Key words
AOCS Ba7-58,GB 13086,cottonseed meal detection,free gossypol content