用射流理论具体论证了大气尘粒子计数器检漏方法(简称漏孔法),普通高效过滤器需要不低于2200粒/L(2.83L/min采样)的上游大气尘浓度,超高效过滤器需要不低于5800粒/L(28.3L/min采样)的上游大气尘浓度。只要扫描特征读数≥1,即可作静止检漏,若再≥3,即可判断为漏。漏孔法比ISO透过率法适用漏孔更小。