Parameters measurement for the thermal neutron beam in the thermal column hole of Xi’an pulse reactor

Science China Technological Sciences(2010)

Cited 2|Views21
No score
Abstract
The distribution of the neutron spectra in the thermal column hole of Xi’an pulse reactor was measured with the time-of-flight method. Compared with the thermal Maxwellian theory neutron spectra, the thermal neutron spectra measured is a little softer, and the average neutron energy of the experimental spectra is about 0.042±0.01 eV. The thermal neutron fluence rate at the front end of thermal column hole, measured with gold foil activation techniques, is about 1.18×10 5 cm −2 s −1 . The standard uncertainty of the measured thermal neutron fluence is about 3%. The spectra-averaged cross section of 197 Au(n, γ) determined by the experimental thermal neutron spectra is (92.8±0.93) ×10 −24 cm 2 .
More
Translated text
Key words
thermal neutron spectra,time-of-flight method,neutron fluence,reactor