微波消解罐铬残留清洗方法的探讨

Chinese Journal of Pharmaceutical Analysis(2012)

Cited 23|Views10
No score
Abstract
目的:确定微波消解罐的最佳清洗方法.方法:分别选用5种清洗方法对消解了不同样品(铬浓度分别为0.7,2.7,4,40 mg·kg-1)的消解罐进行清洗,采用微波消解以原子吸收分光光度计对清洗后消解罐中残留铬的含量进行测定.结果:“盐酸溶液(1→2)浸泡1h,再用硝酸浸泡1h,去离子水清洗3遍”或“用硝酸溶液(1→5)浸泡8~12h,用去离子水清洗3遍”都可以将消解罐中残留的铬清洗干净.结论:“盐酸溶液(1→2)浸泡1h,再用硝酸溶液(1→2)浸泡Ih,去离子水清洗3遍”的清洗方法,既可以节约时间,又可以保证后期实验结果的准确性,可用于铬测定过程中微波消解罐的清洗.