Estimation of thyroid gland volume by spiral computed tomography

R. Hermans, R. Bouillon, K. Laga,P. R. Delaere,B. De Foer, G. Marchal,A. L. Baert

European Radiology(2014)

Cited 44|Views6
No score
Abstract
The objective of this study was to test the accuracy of CT for the estimation of the volume of enlarged thyroid glands. An unenhanced spiral CT scan of neck and upper mediastinum was obtained in 36 patients with an enlarged thyroid gland. By manual segmentation the surface of the thyroid gland on 5-mm-thick slices was calculated; these surfaces were multiplied by the slice interval (10 mm) and summated to obtain the volume of the gland. All patients underwent a total or subtotal thyroidectomy. 1 cm 3 of thyroid gland tissue was considered to weigh 1 g. A good correlation was found between the volume estimated by CT and the weight at pathological examination of the resected gland ( r = 0.98, p < 0.001), with a mean difference of + 12 % (range: + 57.3 to –13.9 %). The volume calculation is reproducible among different observers ( r = 0.99, p < 0.01). Computed tomography allows an easy, reliable and reproducible volume determination of enlarged thyroid glands.
More
Translated text
Key words
Key words: CT,Thyroid abnormalities,Image processing