首次建立了牛奶中64种中性和酸性药物的高效液相色谱-串联质谱(HPLC-MS/MS)同时测定方法。样品中的残留药物用乙腈提取,经正己烷液-液分配除脂和HLB固相萃取柱净化后,以乙腈和甲酸-乙酸铵缓冲溶液为流动相,梯度洗脱,采用HPLC-MS/MS电喷雾正离子(ESI+)电离,多反应监测(MRM)模式检测,基质匹配外标法定量。方法的定量下限(LOQ)为1~100μg/kg,加标回收率为54%~100%,相对标准偏差小于12%。该方法操作简便,灵敏度、准确度、精密度均满足残留分析的要求。