Test Results Of The G-2 Superconducting Solenoid Magnet System

IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY(1997)

引用 7|浏览26
暂无评分
摘要
The g-2 experiment dipole consists of a single 48 turn, 15.1 meter diameter outer solenoid and a pair of 24 turn inner solenoids, 13.4 meters in diameter. The inner solenoids are hooked in series and are run at a polarity that is opposite that of the outer solenoid, thus creating a dipole field in the space between the inner and outer solenoids, The dipole flux is returned by a C shaped continuous iron. The superconducting solenoid coils are closely coupled to the solenoid mandrels and as such are subject to quench back. This report presents the results of various tests on the g-2 magnet system operating within its iron return yoke. These tests include quench back time constant measurements for the inner and outer solenoids and measurements of the response of the two-phase forced cooled helium cryogenic system to magnet quenches. The overall effectivness of the g-2 magnet quench protection system was measured.
更多
查看译文
关键词
cryogenics,superconducting magnets,system testing,iron,time constant,time measurement,magnetic flux,solenoids