Beam Tests Of Ionization Chambers For The Numi Neutrino Beam

Rm Zwaska, J Hall,Se Kopp, M Proga,A Erwin, C Velissaris,D Harris, D Naples,J Mcdonald, D Northacker, M Diwan, B Viren

IEEE Transactions on Nuclear Science(2003)

引用 23|浏览5
暂无评分
摘要
We have conducted tests at the Fermilab Booster of ionization chambers to be used as monitors of the NuMl neutrino beamline. The chambers were exposed to proton fluxes of up to 10(12) particles/cm(2)/1.56mus. We studied potential space charge effects which could reduce signal collection from the chambers at large charged particle beam intensities.
更多
查看译文
关键词
ionization chambers,ionizing radiation,multiplication,neutrinos,particle beam measurements,space charge