Radiation hardness studies of cooling fluids epoxies and capacitors for CMS pixel system

M Atac, B Gobbi, L Cremaldi,J Hoffman

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment(2002)

引用 3|浏览8
暂无评分
摘要
Radiation hardness studies of C6F14 Fluorinert (FC72) fluid, some epoxies and tantalum capacitors were studied for the Compact Muon Solenoidal (CMS) experiment at the Large Hadron Collider (LHC) of CERN. For a successful operation of Forward Silicon Pixel Tracker of the CMS, the cooling fluid, epoxies to be used and the filter capacitors of bias voltage supplies need to be radiation hard. It was also necessary to find out whether the cooling fluid would dissociate under the expected fluence and damage beryllium cooling channels of the Forward Silicon Pixel Discs. This paper is a report of our findings from the performed tests.