Evaluation method of lead measurement accuracy of gears using a wedge artefact

MEASUREMENT SCIENCE AND TECHNOLOGY(2009)

引用 12|浏览4
暂无评分
摘要
The reduction of the vibration and noise of gears is an important issue in mechanical devices such as vehicles and wind turbines. The characteristics of the vibration and noise of gears are markedly affected by deviations of the tooth flank form of micrometer order; therefore, a strict quality control of the tooth flank form is required. The accuracy of the lead measurement for a gear-measuring instrument is usually evaluated using a master gear or a lead master. However, it is difficult to manufacture masters with high accuracy because the helix is a complicated geometrical form. In this paper, we propose a method of evaluating a gear-measuring instrument using a wedge artefact, which includes a highly precise plane surface. The concept of the wedge artefact is described and a mathematical model of the measuring condition of the wedge artefact is constructed. Theoretical measurement results for the wedge artefact are calculated. The wedge artefact is designed and produced on the basis of the theoretical measurement results. A measurement experiment using the wedge artefact is carried out and its effectiveness is verified.
更多
查看译文
关键词
artefact,gear,lead measurement,evaluation,gear-measuring instrument
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper