目的利用眼动追踪仪和红外自动验光仪获得刺激性调节性集合/调节(accommodative convergence/accommodation,AC/A)和反应性AC/A值,分析两者相关性及差异。方法选取34名健康在校学生和年轻工作人员[年龄为20~35岁,平均(25.8±3.4)岁],在集合反馈回路打开(遮盖左眼)的条件下,用310型眼动追踪仪分别记录调节性集合;用wv500红外自动验光仪测量注视眼在各调节刺激下的调节反应,从而分别得出刺激性AC/A和反应性AC/A,对两者数据采用配对t检验进行分析。结果用眼动追踪仪法测量所有受试者所得的刺激性AC/A和反应性AC/A有显著相关性(r=0.871,P=0.000)和明显差异,反应性AC/A为(7.50±3.60)△/D,刺激性AC/A为(4.77±1.84)△/D,反应性AC/A平均值与刺激性AC/A平均值相比为1.57,两者差异有显著统计学意义(P=0.000)。结论反应性AC/A高于刺激性AC/A,大多数个体均有一定程度的调节滞后量。