Arytenoid dislocation after cardiac surgery.

Y Niwa,A Nakae, M Ogawa,M Takashina,S Hagihira,H Ueyama, T Mashimo

Acta Anaesthesiologica Scandinavica(2007)

引用 28|浏览24
暂无评分
摘要
Occurring most usually as complications of upper aerodigestive tract instrumentation during endotracheal intubation or extubation, arytenoid cartilage dislocation and arytenoid subluxation are uncommon laryngeal injuries. Their precise cause, however, is usually difficult to determine. We encountered arytenoid dislocation following cardiac surgery requiring the use of transesophageal echocardiography (TEE). This case prompted us to review some of the mechanisms of injury to the cricoarytenoid joint. We conclude that even very subtle force may dislocate the arytenoid cartilage. We speculate that careless insertion of a TEE probe is mechanically capable of causing arytenoid dislocation and arytenoid subluxation. As ideal tools for intra-operative cardiovascular monitoring, TEE probes are increasingly being used routinely during cardiovascular surgery. So far, arytenoid cartilage dislocation and subluxation following TEE probe insertion have been reported rarely, but complications caused by TEE may increase in the near future. We wish to emphasize the pathophysiological risks of TEE monitoring and other procedures associated with anesthesia, and the need for a proper explanation to achieve informed consent before carrying out TEE monitoring during cardiac surgeries.
更多
查看译文
关键词
anesthesia,arytenoid dislocation,cardiovascular surgery,transesophageal echocardiography