A Highly Reproducible Bolus Immobilization Technique for the Treatment of Scalp Malignancies

Medical Dosimetry(2008)

引用 12|浏览9
暂无评分
摘要
Radiation treatment of scalp malignancies can be a challenge due to the multiple curved surfaces to which homogenous dose must be delivered. The most readily available techniques utilize linear accelerator-based technique of opposed lateral electron field abutting opposed lateral photon field with central blocking. Bolus material is used to achieve adequate skin dose. Although plans to add bolus material often occur in the virtual setting during treatment planning, the practical aspects of reproducibly maintain the bolus material along curved surfaces during the day-to-day patient setup can be a challenge. We present a case of a patient with squamous cell carcinoma of the scalp with neck node involvement treated with surgery followed by adjuvant radiotherapy. We demonstrate a unique immobilization technique that maintains the bolus material on the aquaplast® mesh adherent to the patient’s scalp as well as the neck. TomoTherapy® with daily megavoltage computed tomography (CT) scan was utilized to verify the daily bolus position. We were able to maintain a 95% reproducibility rate. This technique reliably maintains the bolus material on the desired locations with minimum adjustments and manipulation by the therapist and is a technique that can be universally adapatable for conventional radiotherapy or intensity modulated radiation therapy (IMRT) techniques.
更多
查看译文
关键词
Scalp,Bolus,TomoTherapy®,Immobilization
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要