Magnetic field measurements of 1.5 meter model SSC collider dipole magnets at Fermilab

Magnetics, IEEE Transactions  (1992)

引用 5|浏览4
暂无评分
摘要
Magnetic field measurements have been performed at Fermilab on 1.5 m magnetic length model dipoles for the Superconducting Supercollider (SSC). Harmonic measurements are recorded at room temperature before and after the collared cell is assembled into the yoke and at liquid helium temperature. Measurements are made as a function of longitudinal position and excitation current. High field data are compared with room temperature measurements of both the collared coil and the completed yoked magnet and with the predicted fields of both the body of the magnet and the coil ends. The effects of yoking and cold testing agree well with predictions. One of the two cold-tested dipoles satisfies the SSC specification for sextupole/decapole
更多
查看译文
关键词
beam handling equipment,harmonics,magnetic fields,proton accelerators,storage rings,superconducting magnets,synchrotrons,1.5 m,Fermilab,SSC collider dipole magnets,Superconducting Supercollider,cold testing,collared coil,decapole,excitation current,harmonic measurement,liquid He temperature,longitudinal position,magnetic field measurement,model dipoles,sextupole,yoking effect
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要