通过原子力显微镜(AFM)对Nd1.85Ce0.15CuO4±δ(NCCO)单晶样品的微结构进行分析,发现样品在制备和热处理过程中存在分解反应Nd2-xCexCuO4→ (Nd,Ce)2O3+ NdCeO3.5+ Cu2O发生的证据,控制样品冷却速率可得到(Nd,Ce)2O3分解物含量不同的单晶样品. Ab面电阻率测量结果表明,降低冷却速率可有效减少分解过程的发生、减少有效载流子浓度的降低和减少对Cu2O上Cu2+-Cu2+反铁磁关联的破坏,有利于保持体系结构上的均匀性和稳定性,是制备高品质电子型超导体Nd2-xCexCuO4单晶的关键.