The Columbia University Sub-micron Charged Particle Beam.

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment(2009)

引用 30|浏览17
暂无评分
摘要
A lens system consisting of two electrostatic quadrupole triplets has been designed and constructed at the Radiological Research Accelerator Facility (RARAF) of Columbia University. The lens system has been used to focus 6MeV 4He ions to a beam spot in air with a diameter of 0.8μm. The quadrupole electrodes can withstand voltages high enough to focus 4He ions up to 10MeV and protons up to 5MeV. The quadrupole triplet design is novel in that alignment is made through precise construction and the relative strengths of the quadrupoles are accomplished by the lengths of the elements, so that the magnitudes of the voltages required for focusing are nearly identical. The insulating sections between electrodes have had ion implantation to improve the voltage stability of the lens. The lens design employs Russian symmetry for the quadrupole elements.
更多
查看译文
关键词
Microbeam,Quadrupole,Electrostatic,Sub-micron,Charged particle beam