R&D of BEPCII 500 MHz superconducting cavity

Science China Physics, Mechanics and Astronomy(2011)

引用 3|浏览9
暂无评分
摘要
Beijing Electron-Positron Collider Upgrade (BEPCII) adopts two 500 MHz superconducting cavities (SCCs) in each ring for higher accelerated gradient, higher Q and lower impedance (Wang et al. The proceedings of SRF’07). There’s no spare cavity due to the limited time and funding during BEPCII construction. If any serious trouble happened on either one of the two cavities and could not be recovered in a short time, the operation of BEPCII facility will be affected. Therefore, since 2009 three spare cavities have been fabricated in China to ensure reliable operation, and two of them have been successfully vertically tested in January and July 2011. This paper will briefly present the manufacture, post-process and vertical test performance of the 500 MHz spare cavities.
更多
查看译文
关键词
superconducting cavity,spinning,EBW,post-processing