L-12/5-250型压缩机存在各级压缩缸进排气温度较高、机组效率低、运行能耗高等问题,增加了运营成本。基于降低压缩缸的进气温度能降低压缩机功率的结论,提出了冷却压缩机级间回气的节能技术改造方案。结合L-12/5-250型压缩机工艺流程,完成了在第2、4级级间回气管上加装1套冷却器的节能技术改造,并统计了改造前后能耗相关数据。试验数据表明:节能改造后取得了压缩机理论节能1.86%和实际节能3.87%的节能效果,能耗理论计算结果与实测数据吻合。节能改造后降低了压缩缸进排气温度,提高了压缩机效率,降低了机组能耗,实现了压缩机节能运行。