Computer-Aided Diagnosis For Surgical Office-Based Breast Ultrasound

Rf Chang, Wj Kuo,Dr Chen,Yl Huang,Jh Lee,Yh Chou

Archives of surgery (Chicago, Ill. : 1960)(2000)

引用 21|浏览18
暂无评分
摘要
Hypothesis: The computer-aided diagnostic system is an intelligent system with great potential for categorizing solid breast nodules. It can be used conveniently for surgical office-based digital ultrasonography (US) of the breast.Design: Retrospective, nonrandomized study.Setting: University teaching hospital.Patients: We retrospectively reviewed 243 medical records of digital US images of the breast of pathologically proved, benign breast tumors from 161 patients (ie, 136 fibroadenomas and 25 fibrocystic nodules), and carcinomas from 82 patients (ie, 73 invasive duct carcinomas, 5 invasive lobular carcinomas, and 4 intraductal carcinomas). The digital US images were consecutively recorded from January 1, 1997, to December 31, 1998.Intervention: The physician selected the region of interest on the digital US image. Then a learning vector quantization model with 24 autocorrelation texture features is used to classify the tumor as benign or malignant. In the experiment, 153 cases were arbitrarily selected:to be the training set of the learning vector quantization model and 90 cases were selected to evaluate the performance. One experienced radiologist who was completely blind to these cases was asked to classify these tumors in the test set.Main Outcome Measure: Contribution of breast US to diagnosis.Results: The performance comparison results illustrated the following: accuracy, 90%: sensitivity, 96.67%;specificity, 86.67%; positive predictive value, 78.38%; and negative predictive value, 98.11% for the computer-aided diagnostic (CAD) system and accuracy, 86.67%; sensitivity, 86.67%; specificity, 86.67%; positive predictive value, 76.47%; and negative predictive value, 92.86% for the radiologist.Conclusion: The proposed CAD system provides an immediate second opinion. All accurate preoperative diagnosis can be routinely established for surgical office-based digital US of the breast. The diagnostic rate was even better than the results of an experienced radiologist. The high negative predictive rate by the CAD system can avert benign biopsies. It call be easily implemented on exisiting commercial diagnostic digital US machines. For most available diagnostic digital US machines, all that would be required for the CAD system is only a personal computer loaded with CAD software.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要