Performances of the Virgo interferometer longitudinal control system

F. Acernese,F. Antonucci,S. Aoudia,K.G. Arun,P. Astone,G. Ballardin,F. Barone,M. Barsuglia,Th.S. Bauer,M.G. Beker,S. Bigotta,S. Birindelli,M.A. Bizouard,M. Blom,C. Boccara,F. Bondu,L. Bonelli,L. Bosi,S. Braccini,C. Bradaschia,A. Brillet,V. Brisson,R. Budzyński,T. Bulik,H.J. Bulten,D. Buskulic,G. Cagnoli,E. Calloni,E. Campagna,B. Canuel,F. Carbognani,F. Cavalier,R. Cavalieri,G. Cella,E. Cesarini,E. Chassande-Mottin,A. Chincarini,F. Cleva,E. Coccia,C.N. Colacino,J. Colas,A. Colla,M. Colombini,C. Corda,A. Corsi,J.-P. Coulon,E. Cuoco,S. D’Antonio,A. Dari,V. Dattilo,M. Davier,R. Day,R. De Rosa,M. del Prete,L. Di Fiore,A. Di Lieto,M. Di Paolo Emilio,A. Di Virgilio,A. Dietz,M. Drago,V. Fafone,I. Ferrante,F. Fidecaro,I. Fiori,R. Flaminio,J.-D. Fournier,J. Franc,S. Frasca,F. Frasconi,A. Freise,L. Gammaitoni,F. Garufi,G. Gemme,E. Genin,A. Gennai,A. Giazotto,M. Granata,C. Greverie,G. Guidi,H. Heitmann,P. Hello,S. Hild,D. Huet,P. Jaranowski,I. Kowalska, A. Królak,P. La Penna, N. Leroy, N. Letendre, T.G.F. Li, M. Lorenzini, V. Loriette, G. Losurdo,J.-M. Mackowski,E. Majorana,N. Man,M. Mantovani,F. Marchesoni,F. Marion,J. Marque,F. Martelli, A. Masserot,F. Menzinger, C. Michel,L. Milano,Y. Minenkov,M. Mohan,J. Moreau,N. Morgado,A. Morgia,S. Mosca,V. Moscatelli,B. Mours,I. Neri,F. Nocera,G. Pagliaroli,C. Palomba,F. Paoletti,S. Pardi,M. Parisi,A. Pasqualetti,R. Passaquieti,D. Passuello,G. Persichetti,M. Pichot,F. Piergiovanni,M. Pietka,L. Pinard,R. Poggiani,M. Prato,G.A. Prodi,M. Punturo,P. Puppo,O. Rabaste,D.S. Rabeling,P. Rapagnani,V. Re,T. Regimbau,F. Ricci,F. Robinet,A. Rocchi,L. Rolland,R. Romano,D. Rosińska,P. Ruggi,F. Salemi, B. Sassolas,D. Sentenac,R. Sturani,B. Swinkels,A. Toncelli, M. Tonelli,E. Tournefier,F. Travasso,J. Trummer,G. Vajente,J.F.J. van den Brand,S. van der Putten,M. Vavoulidis, G. Vedovato, D. Verkindt, F. Vetrano, A. Viceré, J.-Y. Vinet,H. Vocca,M. Was, M. Yvert

Astroparticle Physics(2010)

引用 8|浏览65
暂无评分
摘要
The performances of the longitudinal sensing and control system of the Virgo gravitational wave detector are described. This system is able to stably maintain the RMS residual fluctuation of the interferometer longitudinal degrees of freedom around or below 10-11m, compatible with the original Virgo requirements. Moreover the detector sensitivity is not limited by longitudinal control noise at any frequency. Indeed the noise re-introduced by the longitudinal control system does not affect the Virgo design sensitivity.
更多
查看译文
关键词
Gravitational waves,Interferometry,Virgo
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要