Performance decay of proton-exchange membrane fuel cells under open circuit conditions induced by membrane decomposition

Journal of Power Sources(2009)

Cited 72|Views14
No score
Abstract
The degradation in performance of proton-exchange membrane fuel cells (PEMFCs) under open circuit conditions was investigated. The oxygen reduction reaction (ORR) kinetic current density at 0.9V was found to decrease from 36 to 4mAcm−2 (geometric) without significant crossover increase or loss in the electrochemically active surface area. Cyclic voltammograms for the electrodes show characteristic changes, e.g. appearance of peaks at ∼0.2V and shift of the onset of platinum oxide formation to higher potentials. It was identified that the large ORR kinetic decay has its origins in the reduction of available Pt sites due to adsorption of anions, which are postulated to be membrane decomposition products such as sulfate ions. Procedures carried out to condense water in the fuel cell led to the expulsion of anions out of the membrane electrode assembly (MEA) resulting in the partial recovery of ORR kinetic current density to 15mAcm−2. In order to attain complete performance recovery of the catalyst, a more effective and practical method to flush out the anions is desirable.
More
Translated text
Key words
Proton-exchange membrane fuel cell,Open circuit,Oxygen reduction reaction,Membrane decomposition,Anion adsorption,Cyclic voltammetry
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined