Measurement And Control Of The Air Contamination Generated In A Medical Cyclotron Facility For Pet Radiopharmaceuticals

HEALTH PHYSICS(2007)

引用 13|浏览5
暂无评分
摘要
The aim of this paper is to report the data concerning the contamination of the exhausted air from the hot cells dedicated to the large-scale synthesis of positron emission tomography (PET) radiopharmaceuticals. Two cyclotrons are currently operating in Ospedale San Raffaele for the routine production of C-11 and F-18. They are linked with four radiochemistry laboratories by means of shielded radioisotope delivery lines. The above labs are dedicated both to the large scale preparation and to the research and development of PET radiopharmaceuticals. The department hosts four CT-PET scanners, which operate with a mean patient workload or 40 per day. Radio-syntheses are performed using automated modules located in 10 hot cells. The air outlets are monitored online by a 2-inch NaI(Tl) counter in a Marinelli geometry counting volume. Contamination values up to 10(5) Bq L-1 have been measured at the hot cell exit point during the synthesis. The corresponding concentrations at the point of release in atmosphere are largely above the threshold of 1.29 Bq L-1, deflned by national regulations as the limit for free environmental release. A shielded gas storage system controlled by a dedicated, customized software program has thus been installed to prevent the potentially hazardous release of gaseous radioactive contaminants. The system has allowed us to maintain the effective dose to neighboring population groups below the limit of 10 mu Sv y(-1).
更多
查看译文
关键词
operational topics, air sampling, contamination, environmental, cyclotron
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要