Four-dimensional fetal echocardiography with spatiotemporal image correlation (STIC): A systematic study of standard cardiac views assessed by different observers

Ultrasound in Obstetrics & Gynecology(2009)

引用 76|浏览7
暂无评分
摘要
Objective. To test the agreement between observers and reproducibility of a technique to display standard cardiac views of the left and right ventricular outflow tracts from four-dimensional volume datasets acquired with Spatiotemporal Image Correlation (STIC). Methods. A technique was developed to obtain dynamic multiplanar images of the left ventricular outflow tract (LVOT) and right ventricular outflow tract (RVOT) from volume datasets acquired with STIC. Volume datasets were acquired from fetuses with normal cardiac anatomy. Twenty volume datasets of satisfactory quality were pre-selected by one investigator. The data was randomly assigned for a blinded review by two independent observers with previous experience in fetal echocardiography. Only one volume dataset was used for each fetus. After a training session, the observers obtained standardized cardiac views of the LVOT and RVOT, which were scored on a scale of 1 to 5, based on diagnostic value and image quality (1 = unacceptable, 2 = marginal, 3 = acceptable, 4 = good, and 5 = excellent). Median scores and interquartile range, as well as inter- and intraobserver agreement were calculated for each view. Results. The mean menstrual age at the time of volume acquisition was 25.5 +/- 4.5 weeks. Median scores ( interquartile range) for LVOT images, obtained by the first and second observers, were 3.5 (2.25 - 5.00) and 4 (3.00 - 5.00), respectively. The median scores ( interquartile range) for RVOT images obtained by the first and second observers were 3 ( 3.00 - 5.00) and 3 (2.00 - 4.00), respectively. The interobserver intraclass correlation coefficient for the LVOT was 0.693 (95% CI 0.380 - 0.822), and 0.696 ( 95% CI 0.382 - 0.866) for the RVOT. For the intraobserver agreement analysis, observer 1 gave higher scores to the LVOT the second time the volumes were analyzed [ LVOT: 3.50 ( 2.25 - 5.00) vs. 5.00 ( 4.00 - 5.00, p = 0.008)]. Conclusion. STIC can be reproducibly used to evaluate fetal cardiac outflow tracts by independent examiners. Slightly better image quality rating scores during the intraobserver variability trial suggests the presence of a learning curve for the manipulation and analysis of volume data obtained by STIC.
更多
查看译文
关键词
three-dimensional ultrasound,four-dimensional ultrasound,STIC,outflow tracts,aorta,pulmonary artery,3D,4D
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要