Rapid and Sensitive UPLC-MS–MS for the Determination of Trimetazidine in Human Plasma

Chromatographia(2010)

引用 11|浏览9
暂无评分
摘要
A specific and sensitive UPLC-MS–MS was developed for the determination of trimetazidine in human plasma. The sample preparation was based on a single-step liquid–liquid extraction with acetic ether. The chromatographic separation was on a C 18 analytical column (50 mm × 2.1 mm, 1.7 μm) with acetonitrile and 10 mM ammonium acetate (30:70, v/v ) as the mobile phase, and a triple-quadrupole mass spectrometer equipped with an electrospray ionization source (ESI) applied for detection. The method was linear over the concentration ranges of 0.25–100.00 ng mL −1 for trimetazidine, and the lower limit of quantification (LLOQ) was 0.25 ng mL −1 . The intra- and inter-day relative standard deviation (RSD) were less than 15% and the relative error (RE) were all within 15%. Finally, this method has been successfully applied to analyze plasma samples from a bioequivalence study with 18 volunteers.
更多
查看译文
关键词
Ultra-performance liquid chromatography-tandem mass spectrometry,Liquid-liquid extraction,Bioequivalence study,Trimetazidine