Vagal hypotension after percutaneous biopsy: Possible confusion with hypovolemic shock
Urologic Radiology(1980)
摘要
Vagal hypotension can occur after percutaneous biopsy and be misdiagnosed as hypovolemia due to hemorrhage. Inappropriate
exploratory surgery and death have resulted. Increased vagal tone or massive discharge is characterized by hypotension with
bradycardia or lack of tachycardia and can occur after many stimuli including contrast medium injection, anxiety, and needle
insertion. Vagal reactions can be mild and self-limited, but can also progress to cardiac arrest. Atropine 0.6 to 0.8 mg intramuscularly
or intravenously in increments up to 3 mg has been recommended for prompt treatment. Volume expansion is adjunctive.
更多查看译文
关键词
Vagal reaction, Percutaneous biopsy, Pseudohemorrhage, Hypovolemic shock, Hypotension and bradycardia