Researchs on Biological Aerated Filter Backwash Process

Ju-wei Peng, Hao Zhang, Xiao-juan Lin

Biomedical Engineering and Biotechnology(2012)

引用 0|浏览0
暂无评分
摘要
Backwash is very important for ensuring the successful performance of biological aerated filter (BAF), in order to the optimal performance after backwash that need 5 ~ 6 h to recover. Through the experiment, combined air-water backwash mode was taken in BAF backwash and water backwash were 5 ~7 L /(m2 ·s) and air backwash 13 ~17 L /(m2 ·s) with the backwash period 24 h and the backwash time 15 min.
更多
查看译文
关键词
force,inductors,filtration,biology,effluents,wastewater treatment,water pollution