Load Characteristics Analysis of the Primary Side of Three Typical Traction Transformers with Various Power Factor Definitions

Intelligent Computation Technology and Automation(2012)

引用 0|浏览0
暂无评分
摘要
Aimed at the nonlinear, asymmetric and fluctuant characteristics of the traction loads, this paper researches and analyzes the loading characteristics and power factor values of V-V, Y-D11 and Impedance-Matching traction transformers by a novel approach. Four definitions of power factor are compared-three considering harmonics and unbalances and one base only on fundamental components. This paper verifies the Impedance-Matching transformer superiority on restraining imbalance from power factor. The simulation results and actual measurement data reveal that, compared with other power factors, according to distort and imbalance, the effective power factor could be recommended for use in fairly evaluating the load characteristics for traction transformers.
更多
查看译文
关键词
electrified railway,traction load,impedance-matching transformer superiority,harmonics,traction transformer,fluctuant characteristic,impedance-matching traction transformers,power factor,transformers,three typical traction transformers,typical traction transformers,load characteristics analysis,traction loads,load characteristics,railway electrification,various power factor definitions,primary side,impedance-matching traction transformer,power factor definitions,power factor value,restraining imbalance,actual measurement data,traction,impedance matching,effective power factor,harmonic analysis,reactive power