Highly Sensitive ?R/R Measurement System for Nano-electro-Mechanical Cantilever Based Bio-sensors

Electronic System Design(2011)

引用 4|浏览0
暂无评分
摘要
Functionalized piezoresistive nano-electromechanical cantilevers are promising tools for sensor applications. This paper reports an integration of custom fabricated piezoresistive cantilever sensors and sensitive analog front end circuit for detection of bio-markers. The system operates on the principles of nano-meter deflection of cantilever sensors, due to antigen-antibody interactions, which in turn exhibits change in piezoresistance. The instrumentation hardware can measure resistance changes down to 14 parts per million (ppm) and maximum sensitivity is 2.134 V/ppm. Experiments have been performed with 90KΩ and 1MΩ base resistances. A wheat stone bridge connected resistors has been used where the functionalized cantilever forms one of the arms. The measured results using this battery operated system has been presented along with calibration technique. The size of this LCD (Liquid crystal display) based system was reduced to fit into a hand held point-of-care form factor. In addition, users can operate this measurement system with the help of computer to connect to the Internet. Measurement results are presented with the introduction of bovine serum albumin (BSA) over the cantilever sensors. This demonstrates the possible application for detection of myocardial infarction in clinical settings.
更多
查看译文
关键词
sensitivity,biosensors,nano-electro-mechanical cantilever,r measurement system,piezoresistive devices,nanosensors,nanometer deflection,wheat stone bridge connected resistors,myocardial infarction,functionalized piezoresistive nanoelectromechanical cantilever,bio-markers detection,bovine serum albumin,measurement result,clinical setting,base resistance,lcd-based system,proteins,resistance 90 kohm,highly sensitive,cantilevers,molecular biophysics,measurement system,functionalized piezoresistive nano-electromechanical cantilever,cantilever sensor,δr-r measurement system,internet,functionalized cantilever,bovine serum albumin (bsa),nano-electromechanical cantilever,calibration technique,point-of-care form factor,clinical settings,sensitive analog front end circuit,instrumentation hardware,piezoresistive cantilever sensor,liquid crystal displays,muscle,ppm,resistance 1 mohm,antigen-antibody interactions,piezoresistive cantilever sensors,peizoresistive,battery operated system,resistors,?r/r measurement,liquid crystal display,point of care,operating system,myocardial infarct,part per million,form factor
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要