Bio
Dr. Lam's research has been involved with improving patient/tumor imaging and also treatment delivery. Image intensifier/television and screen-film systems used in radiology at the time he began his research had limited dynamic range. As a result, image details in some part of the images were more difficult to appreciate. Dr. Lam was the principal investigator in studies on the development of special hardware to reduce the dynamic range of the image so that the image can better match the capability of the imaging device. The same principle can be applied to modern detectors.
Patient setup variations from session to session during multi-fraction radiotherapy is a significant factor in the requirement of expansion of treatment volume from the clinical target volume to a larger planning target volume. Dr. Lam was the principal investigator in studies on improving the automatic determination of patient setup errors with markers and using statistical methods in the correction of setup errors based on imaging. A simplified version of the statistical methods helped guide the establishment of setup error correction protocols for patient treatments.
The understanding of the dependence of the dose delivered to the patient on the collimator setting of x-ray treatment machines is essential in the calculation of how long the treatment machine needs to be turned on for the delivering of the treatment. Dr. Lam led studies in the improvement of the modeling of the treatment machine and methods to measure the contributing factors. Parts of these were used in published practice guidelines.
Patient setup variations from session to session during multi-fraction radiotherapy is a significant factor in the requirement of expansion of treatment volume from the clinical target volume to a larger planning target volume. Dr. Lam was the principal investigator in studies on improving the automatic determination of patient setup errors with markers and using statistical methods in the correction of setup errors based on imaging. A simplified version of the statistical methods helped guide the establishment of setup error correction protocols for patient treatments.
The understanding of the dependence of the dose delivered to the patient on the collimator setting of x-ray treatment machines is essential in the calculation of how long the treatment machine needs to be turned on for the delivering of the treatment. Dr. Lam led studies in the improvement of the modeling of the treatment machine and methods to measure the contributing factors. Parts of these were used in published practice guidelines.
Research Interests
Papers共 55 篇Author StatisticsCo-AuthorSimilar Experts
By YearBy Citation主题筛选期刊级别筛选合作者筛选合作机构筛选
时间
引用量
主题
期刊级别
合作者
合作机构
Photons Plus Ultrasound: Imaging and Sensing 2021 (2021)
John P Gibbons,John A Antolak,David S Followill,M Saiful Huq, Eric E Klein,Kwok L Lam,Jatinder R Palta,Donald M Roback, Mark Reid,Faiz M Khan
Load More
Author Statistics
Co-Author
Co-Institution
D-Core
- 合作者
- 学生
- 导师
Data Disclaimer
The page data are from open Internet sources, cooperative publishers and automatic analysis results through AI technology. We do not make any commitments and guarantees for the validity, accuracy, correctness, reliability, completeness and timeliness of the page data. If you have any questions, please contact us by email: report@aminer.cn