Development of the diagnostic tools for the COMPASS-U tokamak and plans for the first plasma

FUSION ENGINEERING AND DESIGN(2023)

引用 0|浏览59
暂无评分
摘要
The COMPASS-U tokamak (R = 0.894 m, a = 0.27 m, Bt = 5 T, Ip = 2 MA) is a new medium-size device with fully metallic plasma facing components, currently under construction at the Institute of Plasma Physics of the Czech Academy of Sciences in Prague. It features a unique combination of parameters, such as a high temperature of the tokamak walls up to 500 degrees C allowing a high recycling regime, a high magnetic field connected with a high plasma density above 1020 m(-3) and with a high heat flux (perpendicular to divertor targets) density at the outer strike-point up to 90 MW/m(2) in attached conditions. These parameters of the device pose strict constraints and re-quirements on the design of individual diagnostic systems. Strategy and present status of the development of the diagnostic systems for COMPASS-U are provided. Plans for a diagnostic set for the first plasma are reviewed. The review of the diagnostics systems involves the high-temperature compatible slow (up to 20 kHz) and fast (up to several MHz) inductive and non-inductive magnetic sensors (including Thick Printed Copper coils and Hall sensors), the sub-millimetre interferometer with an unambiguous channel, Electron Cyclotron Emission, the interlock and overview cameras, high resolution Thomson scattering, radiation diagnostics (neutron diagnostics, soft and hard X-ray diagnostics, bolometers, impurity monitors, effective ion charge), probe diagnostics (including rail probes) and manipulators.
更多
查看译文
关键词
plasma,diagnostic tools
AI 理解论文